3,029 research outputs found

    The Electromagnetic calorimeter of CMS, Status and performance with cosmics data and first LHC data

    Get PDF
    The CMS detector at the LHC is ready to take physics data. The high resolution Electromagnetic Calorimeter, which consists of 75848 lead tungstate crystals, will play a crucial role in the physics searches undertaken by CMS. The design and the status of the calorimeter will be presented, and its performance in tests with beams, cosmic rays, and data from the first LHC beam

    The Data Quality Monitoring for the CMS Electromagnetic Calorimeter

    Get PDF
    The detector performance of the CMS electromagnetic calorimeter is monitored using applications based on the CMS Data Quality Monitoring (DQM) framework and running on the High-Level Trigger Farm as well as on local DAQ systems. The monitorable quantities are organized into hierarchical structures based on the physics content. The information produced is accessible by client applications according to their subscription requests. The client applications process the received quantities, according to pre-defined analyses, making the results immediately available, while also storing the results in a database, and in the form of static web pages, for subsequent studies. We describe here the functionalities of the CMS ECAL DQM applications and report about their use in real environments

    ECAL Front-End Monitoring in the CMS experiment

    Get PDF
    The CMS detector at LHC is equipped with a high precision lead tungstate crystal electromagnetic calorimeter (ECAL). The front-end boards and the photodetectors are monitored using a network of DCU (Detector Control Unit) chips located on the detector electronics. The DCU data are accessible through token rings controlled by an XDAQ based software component. Relevant parameters are transferred to DCS (Detector Control System) and stored into the Condition DataBase. The operational experience from the ECAL commissioning at the CMS experimental cavern is discussed and summarized

    The CMS Electromagnetic Calorimeter Data Acquisition System at the 2006 Test Beam

    Get PDF
    The Electromagnetic Calorimeter of the CMS experiment at the CERN LHC is an homogeneous calorimeter made of about 80000 Lead Tungstate crystals. From June to November 2006, eleven barrel Supermodules (1700 crystals each) were exposed to beam at CERN SPS, both in stand-alone and in association with portions of the Hadron Calorimeter. We present the description of the system used to configure and readout the calorimeter during this period. The full set of final readout electronics boards was employed, together with the pre-series version of the data acquisition software. During this testbeam, the hardware and software concepts for the final system were validated and the successfull operation of all the ten supermodules was ensured

    ďťżChromosome numbers for the Italian flora: 13

    Get PDF
    In this contribution, new chromosome data obtained on material collected in Italy are presented. It includes the first count for Dianthus carthusianorum subsp. tenorei, Helosciadium nodiflorum, Hieracium hypochoeroides subsp. cilentanum, H. lesimanum, H. scopolioides, H. terraccianoi. In addition, first Italian counts for Crupina vulgaris, Damasonium alisma, and Illecebrum verticillatum are reported

    Intravenous methylprednisolone pulses in hospitalised patients with severe COVID-19 pneumonia, A double-blind, randomised, placebo-controlled trial

    Get PDF
    Rationale: Pulse glucocorticoid therapy is used in hyperinflammation related to coronavirus 2019 (COVID-19). We evaluated the efficacy and safety of pulse intravenous methylprednisolone in addition to standard treatment in COVID-19 pneumonia. Methods: In this multicenter, randomised, double-blind, placebo-controlled trial, 304 hospitalised patients with Covid-19 pneumonia were randomised to receive 1 g of methylprednisolone intravenously for 3 consecutive days or placebo in addition to standard dexamethasone. The primary outcome was the duration of the patient hospitalisation, calculated as the time interval between randomisation and hospital discharge without the need of supplementary oxygen. The key secondary outcomes were survival free from invasive ventilation with orotracheal intubation and overall survival. Results: Overall, 112 of 151 (75.4%) patients in the pulse methylprednisolone arm and 111 of 150 (75.2%) in the placebo arm were discharged from hospital without oxygen within 30 days from randomisation. Median time to discharge was similar in both groups [15 days (95% confidence interval (CI), 13.0 to 17.0) and 16 days (95%CI, 13.8 to 18.2); hazard ratio (HR), 0.92; 95% CI 0.71-1.20; p=0.528]. No significant differences between pulse methylprednisolone and placebo arms were observed in terms of admission to Intensive Care Unit with orotracheal intubation or death (20.0% versus 16.1%; HR, 1.26; 95%CI, 0.74-2.16; p=0.176), or overall mortality (10.0% versus 12.2%; HR, 0.83; 95%CI, 0.42-1.64; p=0.584). Serious adverse events occurred with similar frequency in the two groups. Conclusions: Methylprenisolone pulse therapy added to dexamethasone was not of benefit in patients with COVID-19 pneumonia. Message of the study: Pulse glucocorticoid therapy is used for severe and/or life threatening immuno-inflammatory diseases. The addition of pulse glucocorticoid therapy to the standard low dose of dexamethasone scheme was not of benefit in patients with COVID-19 pneumonia

    Psychological treatments and psychotherapies in the neurorehabilitation of pain. Evidences and recommendations from the italian consensus conference on pain in neurorehabilitation

    Get PDF
    BACKGROUND: It is increasingly recognized that treating pain is crucial for effective care within neurological rehabilitation in the setting of the neurological rehabilitation. The Italian Consensus Conference on Pain in Neurorehabilitation was constituted with the purpose identifying best practices for us in this context. Along with drug therapies and physical interventions, psychological treatments have been proven to be some of the most valuable tools that can be used within a multidisciplinary approach for fostering a reduction in pain intensity. However, there is a need to elucidate what forms of psychotherapy could be effectively matched with the specific pathologies that are typically addressed by neurorehabilitation teams. OBJECTIVES: To extensively assess the available evidence which supports the use of psychological therapies for pain reduction in neurological diseases. METHODS: A systematic review of the studies evaluating the effect of psychotherapies on pain intensity in neurological disorders was performed through an electronic search using PUBMED, EMBASE, and the Cochrane Database of Systematic Reviews. Based on the level of evidence of the included studies, recommendations were outlined separately for the different conditions. RESULTS: The literature search yielded 2352 results and the final database included 400 articles. The overall strength of the recommendations was medium/low. The different forms of psychological interventions, including Cognitive-Behavioral Therapy, cognitive or behavioral techniques, Mindfulness, hypnosis, Acceptance and Commitment Therapy (ACT), Brief Interpersonal Therapy, virtual reality interventions, various forms of biofeedback and mirror therapy were found to be effective for pain reduction in pathologies such as musculoskeletal pain, fibromyalgia, Complex Regional Pain Syndrome, Central Post-Stroke pain, Phantom Limb Pain, pain secondary to Spinal Cord Injury, multiple sclerosis and other debilitating syndromes, diabetic neuropathy, Medically Unexplained Symptoms, migraine and headache. CONCLUSIONS: Psychological interventions and psychotherapies are safe and effective treatments that can be used within an integrated approach for patients undergoing neurological rehabilitation for pain. The different interventions can be specifically selected depending on the disease being treated. A table of evidence and recommendations from the Italian Consensus Conference on Pain in Neurorehabilitation is also provided in the final part of the pape

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated

    Measurement of the Forward-Backward Asymmetry in the B -> K(*) mu+ mu- Decay and First Observation of the Bs -> phi mu+ mu- Decay

    Get PDF
    We reconstruct the rare decays B+→K+μ+μ−B^+ \to K^+\mu^+\mu^-, B0→K∗(892)0μ+μ−B^0 \to K^{*}(892)^0\mu^+\mu^-, and Bs0→ϕ(1020)μ+μ−B^0_s \to \phi(1020)\mu^+\mu^- in a data sample corresponding to 4.4fb−14.4 {\rm fb^{-1}} collected in ppˉp\bar{p} collisions at s=1.96TeV\sqrt{s}=1.96 {\rm TeV} by the CDF II detector at the Fermilab Tevatron Collider. Using 121±16121 \pm 16 B+→K+μ+μ−B^+ \to K^+\mu^+\mu^- and 101±12101 \pm 12 B0→K∗0μ+μ−B^0 \to K^{*0}\mu^+\mu^- decays we report the branching ratios. In addition, we report the measurement of the differential branching ratio and the muon forward-backward asymmetry in the B+B^+ and B0B^0 decay modes, and the K∗0K^{*0} longitudinal polarization in the B0B^0 decay mode with respect to the squared dimuon mass. These are consistent with the theoretical prediction from the standard model, and most recent determinations from other experiments and of comparable accuracy. We also report the first observation of the Bs0→ϕμ+μ−decayandmeasureitsbranchingratioB^0_s \to \phi\mu^+\mu^- decay and measure its branching ratio {\mathcal{B}}(B^0_s \to \phi\mu^+\mu^-) = [1.44 \pm 0.33 \pm 0.46] \times 10^{-6}using using 27 \pm 6signalevents.Thisiscurrentlythemostrare signal events. This is currently the most rare B^0_s$ decay observed.Comment: 7 pages, 2 figures, 3 tables. Submitted to Phys. Rev. Let

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore